EN500/EN600 frequency inverter used for Screw Air compressor

As an air source device, air compressor is the heart of pneumatic system. It’s a basic product of industrial modernization which converts the original mechanical energy to air pressure energy. Air compressor widely used for production line, machine tool and all applications which need compressed air.

  1.  Applications of Air compressor

As an air source device, air compressor is the heart of pneumatic system. It’s a basic product of industrial modernization which converts the original mechanical energy to air pressure energy. Air compressor widely used for production line, machine tool and all applications which need compressed air.

2. Process of Air compressor operation

2.1  Suction process

With the rotor rotating, air comes into the compressor from the inlet port, which is suction. The suction process completed when air full of the space between male rotor and female rotor.​

2.2  Compression process

The convex lobes of the male rotor start to mesh with the concave cavities of the female rotor to compress the entrapped air.

 

2.3  Discharge process

The compression motion of male rotor decreases the volume of air gradually and extrudes the entrapped air to outlet to complete the discharge process.

1.jpg

3. EN500/EN600 Introduction

EN500/EN600 series high-performance flux vector inverter adopt advanced control mode to achieve high torque ,high precision and wide-range speed regulation drive, realizing PG closed-loop vector control and non-PG open-loop vector control. Speed vector, torque vector two operation modes available, it can limit the shock current quickly, which widely used for top manufacturing industry. EN500/EN600 series inverter has high control precision, fast speed response, good features at low frequency and intelligent inspection and protection functions. Abundant extend cards for choose, like field bus extend cards, terminal extend cards, relays extend cards and analog extend card.

 

 

 

3.1 Shortage of traditional air compressor during operation

Large start current of main motor which has influence on the stable of power grid and the safety operations of others electric equipment.

The work is fruitless when air compressor unloading and the consumed electrical power completely be wasted.

Large noise occurs when air compressor operates with grid power supply.

Much shock to device when start-up with grid power supply. Greater maintenance needed for device.

3.2 EN500/EN600 frequency inverter wiring for air compressor

 

2.jpg

 

3.3 EN500/EN600 Parameters Setup

Auto-tuning parameters setup under Vector Control ​

Function CodeSet RangeExplanation
F00.002Select senior list mode
F00.241SVC vector control mode
F15.O1Base on motor typeMotor rated power
F15.02Base on motor typeMotor rated voltage
F15.03​ Base on motor typeMotor rated current
F15.04Base on motor typeMotor rated frequency
F15.05Base on motor typeMotor rated speed
F15.06Base on motor typeMotor pairs of pole
F15.191Motor static auto-tuning mode

 

Constant pressure air supply PID parameters setup

Function CodeSet RangeExplanation
F11.001PID Close-loop control valid
F11.016Select communication provision for pressure
F11.020Select AI1 as pressure feedback signal

 

3.4 The advantages of EN500/EN600 for Air compressor application

Vector control mode with fast response and stable operation ;

Frequency inverter parameters and system control parameters can be setup by HMI;

Advantaged pressure PID control function ensure stable air supply from air compressor device ;

Good soft starting function avoids mechanical shock and reduces noise ;

With smart sleeping function and all kinds of operation protection function.